油井探勘

現今的石油和天然氣行業,如石油探勘、開採、鑽井系統中,密封件通常用於具有高壓、極端溫度、腐触性化學物質和氣體等嚴苛的應用環境,使得密封彈性體性能的要求越來越高。

長泓提供一系列經過經過 Element Hitchin 第三方認證機構的獨立測試,和通過ISO 23936-2規範認證的快速氣體滅壓( RGD) 驗證材料,如HNBR. FKM. AFLAS。

Model CHR-HN-002 CHR-AF-001 CHR-FK-003 CHR-FK-002 CHR-FK-004
Material HNBR AFLAS FKM FKM FKM
Curing System Peroxide Peroxide Bisphenol Peroxide Peroxide
Durometer 90 90 90 90 90
Chemical Resistantance Medium Excellent Medium Excellent Excellent
Steam Medium Excellent Medium Good Good
Aromatic Hydrocarbons Medium Medium Excellent Excellent Excellent
Amines Excellent Excellent Medium Medium Medium
Oil Excellent Excellent Excellent Excellent Excellent
Methanol Good Excellent Medium Medium Medium
Sealing Medium Good Excellent Excellent Excellent
Service Temperature -30 to 150℃ 0 to 225℃ -15 to 200℃ -30 to 200℃ -40 to 200℃
ISO 23936-2* PASS PASS PASS PASS PASS

*RGD Testing Conditions: Gas: 10% C02+90% CH4, Pressure: 15MPa. Termperature: 100℃

快速氣體滅壓(RGD)

適用於石油與天然氣行業的特殊橡膠

高壓環境下,氣體會滲透進彈性體內部,而當彈性體所處的高壓環境的壓力迅速釋放減壓時,彈性體中的壓福氣體試圖擴大並衝出彈性體,導致其破裂。 這種現象被稱為快速氣驓減壓(RGD)或爆炸性減壓 (ED)

RGD容易導致密封件產生現裂痕或不可見的內部損壞,進而使密封件失效,造成石油和天然氣行業設備停擺或損壞,因此抵抗RGD的能力為該行業的必備指標之一。

O型圈不耐RGD導致爆裂的圖例(側面及截面圖)

訂閱電子報

在按下”訂閱”時,表示我已詳閱並充分瞭解隱私權政策

確認送出