DUPONT

Medical-Grade Silicone Rubber

The Liveo™ medical-grade product can be used in many medical devices. It is provided with a complete set of biocompatibility test report to ensure its safety and performance.

  • Observe the ISO 10993 biocompatibility standards Raw materials are produced at a FDA-certified factory in Michigan, USA
DUPONT Medical-Grade Silicone Rubber

Solid Silicone Rubber - Medical-Grade

Liveo QP1 HCR

Single-component | Platinum/peroxide-bridged | Applicable to Class A medical device | Product not implanted in the human body

Hardness: 30~70

Biocompatibility:

  • Cytotoxicity USP Class V and VI Food Grade Compliance

Model

  • Liveo™ QP1-30 HCR Liveo™ QP1-50 HCR Liveo™ QP1-60 HCR Liveo™ QP1-70 HCR
Liveo C6 HCR

Single/bi-component (by product) | Platinum/peroxide-bridged (by product) | Applicable to Class A and Class B medical devices | Can be implanted for a short period of time (≤29 days)

Hardness: 35~80

Biocompatibility:

  • Cytotoxicity Skin Sensitization USP Class V and VI Food Grade Compliance 30-Day Implant Substance Soluble in Hexane Volatile Matter

Model - bi-component

  • Liveo™ C6-135 HCR Liveo™ C6-150 HCR Liveo™ C6-165 HCR Liveo™ C6-180 HCR

Model - single-component

  • Liveo™ C6-235 HCR Liveo™ C6-250 HCR Liveo™ C6-265 HCR
Liveo Biomedical Grade HCR

Single/bi-component (by product) | Platinum/peroxide-bridged (by product) | Applicable to Class A, Class B and Class C medical devices | Can be implanted for a short period of time (≤29 days)

Hardness: 20~80

Biocompatibility:

  • Cytotoxicity Skin Sensitization USP Class V and VI Food Grade Compliance Hemolysis 90-Day Implant Substance Soluble in Hexane Volatile Matter Mutagenicity / Genotoxicity Pyrogenicity (USP)

Model - bi-component

  • Liveo™ Q7-4720 HCR Liveo™ Q7-4735 HCR Liveo™ Q7-4750 HCR Liveo™ Q7-4765 HCR Liveo™ Q7-4780 HCR

Model - single-component

  • Liveo™ Q7-4535 HCR Liveo™ Q7-4550 HCR Liveo™ Q7-4565 HCR

Liquid Silicone Rubber - Medical-Grade

Liveo QP1 LSR

Bi-component | Platinum-bridged | Applicable to Class A medical device | Product not implanted in the human body

Hardness: 20~75

Biocompatibility:

  • Cytotoxicity USP Class V and VI Food Grade Compliance

Model - universal

  • Liveo™ QP1-20 LSR Liveo™ QP1-30 LSR Liveo™ QP1-40 LSR Liveo™ QP1-50 LSR Liveo™ QP1-60 LSR Liveo™ QP1-70 LSR Liveo™ QP1-75 LSR

Model - Low viscosity

  • Liveo™ QP1-230 LSR Liveo™ QP1-240 LSR Liveo™ QP1-250 LSR Liveo™ QP1-260 LSR Liveo™ QP1-270 LSR
Liveo C6 LSR

Bi-component | Platinum-bridged | Applicable to Class A and Class B medical devices | Can be implanted for a short period of time (≤29 days)

Hardness: 30~70

Biocompatibility:

  • Cytotoxicity Skin Sensitization USP Class V and VI Food Grade Compliance 30-Day Implant Substance Soluble in Hexane Volatile Matter

Model

  • Liveo™ C6-530 LSR Liveo™ C6-540 LSR Liveo™ C6-550 LSR Liveo™ C6-560 LSR Liveo™ C6-570 LSR
Liveo Biomedical Grade LSR

Bi-component | Platinum-bridged | Applicable to Class A, Class B and Class C medical devices | Can be implanted for a short period of time (≤29 days)

Hardness: 30~70

Biocompatibility:

  • Cytotoxicity Skin Sensitization USP Class V and VI Food Grade Compliance Hemolysis 90-Day Implant Substance Soluble in Hexane Volatile Matter Mutagenicity / Genotoxicity Pyrogenicity (USP)

Model

  • Liveo™ 7-6830 LSR Liveo™ 7-6840 LSR Liveo™ 7-6860 LSR Liveo™ 7-4860 LSR Liveo™ 7-4870 LSR Liveo™ Q7-4840 LSR Liveo™ Q7-4850 LSR Liveo™ Q7-7840 LSR Liveo™ Q7-7850 LSR Liveo™ Q7-7870 LSR

Medical-Grade Adhesive

Liveo Soft Skin Adhesive

Silicone adhesive | Bi-component | Platinum-bridged | Can be removed from the skin easily | No residual glue left

Common application: Wound dressing

Biocompatibility:

  • Cytotoxicity Skin Irritation Skin Sensitization

Model - universal

  • Liveo™ 7-9700 Soft Skin Adhesive Liveo™ MG 7-9800 Soft Skin Adhesive Liveo™ MG 7-9850 Soft Skin Adhesive

Model - enhanced viscosity

  • Liveo™ MG 7-9900 Soft Skin Adhesive Liveo™ MG 7-9960 Soft Skin Adhesive
Liveo RTV Adhesive

Silicone adhesive | Moisture curing | Room-temperature curing | No solvent

Applicable to cured silicone to silicone bonding

Model

  • Liveo™ Medical Adhesive Type A

Medical-Grade Silicone Oil

Liveo Medical GradeFluids Emulsions Dispersions Topical Excipients

Liveo medical-grade silicone oil | A wide range of applications | With a complete set of biocompatibility report

Application: Lubrication | Thinning | Cleaning | Mold release | Surface treatment

Model and Viscosity

  • Liveo™ 360 Medical Fluid (Viscosity: 20cst, 100cst, 350cst, 1000cst, 12500cst) Liveo™ Q7-9180 Silicone Fluid (Viscosity: 0.65cst, 1cst) Liveo™ MDX4-4159 50% Medical Grade Dispersion Liveo™ Q7-9120 Silicone Fluid (Viscosity: 20cst, 100cst, 350cst, 1000cst, 12500cst)

Subscribe to Newsletter

When I press "Subscribe", I have read and fully understood the contentsPrivacy Policy

Submit